21 resultados para Radiation

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results of permittivity measurements, electromagnetic interference shielding effectiveness, and heat generation due to microwave absorption in conducting polymer coated textiles are reported and discussed. The intrinsically conducting polymer, polypyrrole, doped with anthraquinone-2-sulfonic acid (AQSA) or para-toluene-2-sulfonic acid (pTSA) was applied on textile substrates and the resulting materials were investigated in the frequency range 1–18 GHz. The 0.54 mm thick conducting textile/polypyrrole composites absorbed up to 49.5% of the incident 30–35 W microwave radiation. A thermography station was used to monitor the temperature of these composites during the irradiation process, where absorption was confirmed via visible heat losses. Samples with lower conductivity showed larger temperature increases caused by microwave absorption compared to samples with higher conductivity. A sample with an average sheet resistivity of 150 Ω/sq. showed a maximum temperature increase of 5.27 °C, whilst a sample with a lower resistivity (105 Ω/sq.) rose by 3.85 °C.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For various applications it is necessary to know not only global solar radiation values, but also the diffuse and beam components. Because often only global values are available, there have been several models developed to establish correlations between the diffuse fraction and various predictors. These typically include the clearness index, but also may include the solar angle, temperature and humidity. The clearness index is the proportion of extraterrestrial radiation reaching a location, where the extraterrestrial value used in the calculation varies with latitude and time of year. These correlations have been developed using data principally from latitudes greater than 40°, often using only data from a few locations and with few exceptions have not used solar altitude as a predictor. Generally the data consist of hourly integrated values. A model has been developed using hourly data from a weather station set up at Deakin University, Geelong. Another model has also been developed for 15 minute data values in order to ascertain if the smoothing generated by using hourly data makes a significant difference to overall results. The construction of such models has been investigated, enabling an extension to the research, inclusive of other stations, to be performed systematically. A final investigation was carried out, using data from other Australian locations, to explain some of the considerable scatter by adding apparent solar time as a predictor, which proved to be significantly better than solar altitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study are (1) to establish a reliable and valid quality-of-life (QOL) questionnaire for Chinese patients with head and neck (H&N) cancer who are treated with radiation therapy and (2) to evaluate the impact of the immediate side effects of treatment on the QOL of these patients. The 39-item "Quality of Life Radiation Therapy Instrument with Head and Neck Companion Module" (QOL-RTI/H&N) was translated into Chinese. In the reliability evaluation phase (study module 1), the questionnaire was administered twice to 56 H&N cancer patients, 7 days apart, during the second and third week of radiation therapy. In the validity evaluation phase (study module 2), 138 patients completed the QOL-RTI/H&N before starting and at the end of radiation therapy. Sixty-nine of these 138 patients also completed the QOL-RTI/H&N during the second week of their radiation therapy, at the same time as completing the Functional Assessment of Cancer Therapy-Head and Neck (FACT-H&N) questionnaire. Cronbach alpha coefficients were 0.88 for the general-tool QOL-RTI and 0.90 for the H&N subscale. Test-retest reliability was satisfactory with intraclass correlation coefficients of 0.89 for the general-tool QOL-RTI and 0.75 for the H&N subscale. The instrument can discriminate between patients with stage I or II disease and those with stage III or IV disease (P < .05). Concurrent validity was established by the good agreement with the FACT-H&N (r = 0.86, P < .001). A highly significant deterioration was in the QOL from the baseline to the end of treatment (mean difference for general tool = 1.95, P < .001; mean difference for H&N subscale = 4.85, P < .001). The Chinese QOL-RTI/H&N is a reliable and valid tool for determining the QOL in H&N cancer patients receiving radiation therapy. The immediate side effects of treatment had a significantly negative impact on the patients' QOL. The impact was relatively large for the functional and treatment-site aspects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperature changes in conducting polypyrrole/para-toluene-2-sulphonic acid (PPy/pTSA) coated nylon textiles due to microwave absorption in the 8–9 GHz and 15–16 GHz frequency ranges were obtained by a thermography station during simultaneous irradiation of the samples. The temperature values are compared and related to the amounts of reflection, transmission and absorption obtained with a non-contact free space transmission technique, indicating a relationship between microwave absorption and temperature increase. Non-conductive samples showed no temperature increase upon irradiation irrespective of frequency range. The maximum temperature difference of around 4 °C in the conducting fabrics relative to ambient temperature was observed in samples having 48% absorption and 26.5 ± 4% reflection. Samples polymerized for 60 or 120 min with a dopant concentration of 0.018 mol/l or polymerized for 180 min with a dopant concentration of 0.009 mol/l yielded optimum absorption levels. As the surface resistivity decreased and the reflection levels increased, the temperature increase upon irradiation reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an emergency department (ED), computed tomography (CT) is particularly beneficial in the investigation of high-speed trauma patients. With the advent of multidetector CT (MDCT) scanners, it is becoming faster and easier to conduct scans. In recent years, this has become evident with an increasing number of CT requests. Patients who have multiple CT scans during their hospital stay can receive radiation doses that have an increased theoretical risk of induction of cancer. It is essential that the clinical justification for each CT scan be considered on an individual basis and that due consideration is given to the radiation risk and possible diagnostic benefit. The current lack of a central State or Commonwealth data repository for medical images is a contributing factor to excessive radiation dosage to the population. The principles of justification and radiation risks are discussed in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cylinder-planar Ge waveguides are being developed as evanescent-wave sensors for chemical microanalysis. The only non-planar surface is a cylinder section having a 300-mm radius of curvature. This confers a symmetric taper, allowing for direct coupling into and out of the waveguide's 1-mm2 end faces while obtaining multiple reflections at the central <30-μm-thick sensing region. Ray-optic calculations indicate that the propagation angle at the central minimum has a strong nonlinear dependence on both angle and vertical position of the input ray. This results in rather inefficient coupling of input light into the off-axis modes that are most useful for evanescent-wave absorption spectroscopy. Mode-specific performance of the cylinder-planar waveguides has also been investigated experimentally. As compared to a blackbody source, the much greater brightness of synchrotron-generated infrared (IR) radiation allows a similar total energy throughput, but restricted to a smaller fraction of the allowed waveguide modes. However, such angle-selective excitation results in a strong oscillatory interference pattern in the transmission spectra. These spectral oscillations are the principal technical limitation on using synchrotron radiation to measure evanescent-wave absorption spectra with the thin waveguides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim  To identify the factors that contribute to variation in abundance (population density), and to investigate whether habitat breadth and diet breadth predict macroecological patterns in a suborder of passerine birds (Meliphagoidea).
Location  Australia (including Tasmania).
Methods  Mean abundance data were collated from site surveys of bird abundance (the Australian Bird Count); range size and latitudinal position data from published distribution maps; and body mass and diet breadth information from published accounts. A diversity index of habitats used (habitat breadth) was calculated from the bird census data. We used bivariate correlation and multiple regression techniques, employing two phylogenetic comparative methods: phylogenetic generalized least squares and independent contrasts.

Results  Body mass and latitude were the only strong predictors of abundance, with larger-bodied and lower-latitude species existing at lower densities. Together, however, body mass and latitude explained only 11.1% of the variation in mean abundance. Range size and habitat breadth were positively correlated, as were diet breadth and body mass. However, neither range size, nor habitat breadth and diet breadth, explained patterns in abundance either directly or indirectly.
Main conclusions  Levels of abundance (population density) in meliphagoid birds are most closely linked to body mass and latitudinal position, but not range size. As with many other macroecological analyses, we find little evidence for aspects of niche breadth having an effect on patterns of abundance. We hypothesize that evolutionary age may also have a determining effect on why species tend to be rarer (less abundant) in the tropics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The uppermost 5-15 m of the Douling Formation in the southern Hunan area. South China, yields a diverse fauna comprised of ammonoids, bivalves, and brachiopods. The brachiopods reported in this paper consist of 51 species in 34 genera and are dominated by the Lopingian (Late Permian) species associated with a few species persisting from the underlying Maokouan (Late Guadalupian). This fauna is of earliest Wuchiapingian in age as precisely constrained by the associated conodont Clarkina postbitteri postbitteri and the Guadalupian-type ammonoid fauna of the Roadoceras-Doulingoceras Zone in the brachiopod horizon. The discovery of the Lopingian species-dominated brachiopod fauna in the earliest Wuchiapingian in southern Hunan suggests a much less pronounced effect of the pre-Lopingian crisis (end-Guadalupian mass extinction) than the end-Changhsingian mass extinction in terms of brachiopods, a contemporaneous onset of the Lopingian recovery/radiation during the pre-Lopingian crisis period, and taxonomic selectivity of the pre-Lopingian crisis in terms of different fossil groups. New taxa are Echinauris doulingensis n. sp., Pararigbyella quadrilobata n. gen. and n. sp. and P. doulingensis n. gen. and n. sp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrospun polyelectrolyte hydrogel nanofibres are being developed for many applications including artificial muscles, scaffolds for tissue engineering, wound dressings and controlled drug release. For electrospun polyelectrolytes, a post-spinning crosslinking process is necessary for producing a hydrogel. Typically, radiation or thermal crosslinking routines are employed that require multifunctional crosslinking molecules and crosslink reaction initiators (free radical producers). Here, ultraviolet subtype-C (UVC) radiation was employed to crosslink neat poly(acrylic acid) (PAA) nanofibres and films to different crosslink densities. Specific crosslink initiators or crosslinking molecules are not necessary in this fast and simple process providing an advantage for biological applications. Scanning probe microscopy was used for the first time to measure the dry and wet dimensions of hydrogel nanofibres. The diameters of the swollen fibres decrease monotonically with increasing UVC radiation time. The fibres could be reversibly swollen/contracted by treatment with solutions of varying pH, demonstrating their potential as artificial muscles. The surprising success of UVC radiation exposure to achieve chemical crosslinks without a specific initiator molecule exploits the ultrathin dimensions of the PAA samples and will not work with relatively thick samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We determined the stability of infectious hematopoietic necrosis virus (IHNV) and viral hemorrhagic septicemia virus (VHSV) suspended in either fish processing plant effluent blood water (EBW) or culture media and examined the effectiveness of UVC radiation to inactivate IHNV and VHSV suspended in both solutions. Without exposure to UVC, IHNV and VHSV were maintained in 4°C blood water for up to 48 hours without significant reduction in virus titer. However when exposed to UVC radiation using a low pressure mercury vapour lamp collimated beam, IHNV and VHSV were inactivated, and the efficacy of UVC radiation was dependent upon the solution and virus type being treated. A 3-log reduction for VHSV and IHNV in culture media was achieved at 3.28 and 3.84 mJ cm-2, respectively. The UV dose needed for a 3-log reduction of VHSV in EBW was 3.82 mJ cm-2. However, exposure of IHNV in EBW to the maximum UVC dose tested (4.0 mJ cm-2) only led to a 2.26-log-reduction. Factors such as particle size, and possible association of viruses with suspended EBW particulate, were not investigated in this study, but may have contributed to the difference in UVC effectiveness. Future work should emphasize improved filtration methods prior to UV treatment of processing plant EBW at an industrial scale.